Basic Info.
Model NO.
                                     Mi550
                                 Display
                                     Digital
                                 Installation
                                     Direct Connected
                                 Usage
                                     Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
                                 Electric Equipment
                                     Three-phase Four-wire
                                 Theory
                                     Electronic Meter
                                 Measured Signal
                                     Continuous Wave
                                 Type
                                     Energy Meter
                                 Certification
                                     RoHS, ISO, CE
                                 Customized
                                     Customized
                                 Current Sensor
                                     333mv CT/ Rogowski Coil
                                 Storage
                                     32GB Memory,USB Disk Download
                                 Power Quality
                                     Voltage Swell and DIP, Waveform Display
                                 Graphs Display
                                     Waveform, Vector Diagram and Histogram Display
                                 Power Supply 1
                                     2*18650 Lithium Battery
                                 Power Supply 2
                                     5VDC, 2A Power Supply(Included Adaptor)
                                 Rated Current
                                     0-18000A
                                 Voltage Range
                                     0-600VAC
                                 Current Input
                                     BNC Connector
                                 Voltage Input
                                     Banana Plug
                                 Communication Protocol
                                     Modbus TCP, Ethernet RJ45 Port
                                 Sampling Rate
                                     8K Samples Per Second
                                 Harmonic
                                     50th in The Mean Time
                                 Wiring System
                                     3p4w, 3p3w, 1p2w
                                 Frequency
                                     45...65 Hz
                                 Transport Package
                                     Carton
                                 Specification
                                     850g (with Accessory 2kgs)
                                 Trademark
                                     MEATROL
                                 Origin
                                     China
                                 HS Code
                                     9030331000
                                 Production Capacity
                                     50000PCS/Year
                                 Product Description
 
       World-famous manufacturer
Three major production bases in Shanghai, Chongqing, and Zhejiang
Looking forward to in-depth communications, project cooperation, and exclusive agency
                                                                                                                                  Contact:  Susan    Three major production bases in Shanghai, Chongqing, and Zhejiang
Looking forward to in-depth communications, project cooperation, and exclusive agency
 
       Mi550 Characteristics:   
       1 Handheld power quality analyzer   
       2 Built-in lithium batteries   
       3 Built-in 32GB memory   
       4 Export data from a USB flash drive   
       5 4 inch IPS display   
       6 CO2 emission factor   
       7 Support Chinese, English, multilingual display   
       8 Communication: RJ45-Ethernet, Modbus-TCP/IP   
       9 Data, event, 1-50 harmonic values and waveform record.   
       10 Graphs : waveform, vector diagram and histogram display   
       1)Power quality:Voltage swell and dip   
       (Record time, amplitude value, voltage RMS 1/2 value of each phase and voltage waveform of each phase)   
       2)   
       Waveform display Ua,Ub,Uc,Ia,Ib,Ic   
       Waveform reading (UDP protocol)   
       11 Accessories: 5pcs voltage clamp, adaptor, 5pcs magnetic probe   
       12 The internal electric energy chip: the world's top ADE9000 chip    
                            
                    
                                       
                    
                  
    
       
       
       
      - Product description
- Support systems of single-phase and three-phase. It can measure multiple electrical parameters such as current, voltage, power factor, power, energy, and power quality parameters including harmonic, unbalance degree, voltage swell and voltage dip, etc.
- In addition to the measurement function, Mi550 is equipped with various records, such as waveform records and programmable interval measurement value records. To store and record data, it is internally embedded 32 GB memory card.
- With standard configuration of RJ45 Ethernet communication interface, through standard Modbus TCP protocol, it is compatible with various configuration systems and could transmit the electrical parameters collected by the front end to the system data center in real time.      - General parameters
 
| Product name | |
| Model No. | Mi550 | 
| Type | Handheld Three phase power quality analyzer | 
| Application field | |
| Application field | Power analysis, Power measurement, Power quality analysis | 
| Wiring mode | |
| Wiring system | 3P4W_4CT 3P4W_3CT 3P3W_3CT 3P3W_2CT 1P2w | 
| Current sensor | Rogowski coil Voltage-output current clamp | 
| Voltage access | Direct access Connected through voltage transformer | 
| Storage | |
| Type | TF card | 
| Capacity | 32GB | 
| Data export | U disk export (U disk file is FAT32 system) | 
| Communication | |
| Interface | RJ45- Ethernet | 
| Protocol | Modbus-TCP | 
| Power Supply | |
| Adapter input | 5VDC, 2A | 
| Battery | Rechargeable lithium battery, specification 18650, 2 pcs, capacity about 4000mAh | 
| Battery purely working time | ≥6h | 
| Battery charging time (off state) | ≤5h | 
| Power saving mode | The brightness of the screen backlight is adjustable. The automatic screen off time is adjustable. | 
| Display | |
| Size | 3.97 inch | 
| Type | IPS display | 
| Resolution ratio | 480*800 | 
| Machinery | |
| Dimention | 215*130*60mm | 
| Weight | 850g | 
| Environment | |
| Working environment | Temperature-20ºC~+55ºC, Humidity below 90% RH | 
| Storage environment | Temperature-40ºC~+70ºC, Humidity below 95% RH(non-condensing) | 
| Altitude | ≤2km | 
| Measurement category | CAT III 600V | 
| IP code | IP30 | 
-      - Measurement parameters
 
| Real-time measurement data | |
| Voltage | Phase voltage: Phase ABC N phase to ground voltage Line voltage: UAB, UBC, UCA Voltage peak coefficient: Phase ABC Voltage peak: Phase ABC | 
| Current | Phase current: Phase ABCN Current peak coefficient: Phase ABC K Factor: Phase ABC | 
| Frequency | Line frequency | 
| Power | Active power: Phase ABC and total Reactive power: Phase ABC and total Apparent power: Phase ABC and total | 
| Power factor | Phase ABC and total | 
| Fundamental harmonic power factor | Phase ABC and total | 
| Electrical energy | Active Energy: Phase ABC and total (import / export) Reactive energy: Phase ABC and total (import / export) Apparent Energy: Phase ABC and total CO2 emissions | 
| Harmonic measurement data | |
| Voltage harmonics | THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1-50th harmonic percentage, phase ABC 1-50th harmonic voltage value | 
| Current harmonics | THD (Total harmonic percentage), TOHD (Odd total harmonic percentage), TEHD (Even total harmonic percentage), phase ABC 1- 50th harmonic percentage, phase ABC 1-50th harmonic current value | 
| Waveform | |
| Voltage waveform | Phase ABC voltage waveform or UAB, UBC, UCA line voltage waveform | 
| Current waveform | Phase ABC current waveform | 
| Phase angle | |
| Voltag pehase angle | Phase ABC | 
| Current pehase angle | Phase ABC | 
| Phase angle between voltage and current | Phase ABC | 
| Unbalance | |
| Unbalance | Voltage unbalance, current unbalance | 
| Demand | |
| Power demand and peak demand | Phase ABC active power and total power, phase ABC reactive power and total power, phase ABC apparent power and total power | 
| Current demand and peak demand | Phase ABC | 
-      - Parameter accuracy
 
| Parameter | Type | Description | 
| Voltage | Channel input voltage range | 0-600VAC | 
| Measurement range | 0-600VAC | |
| Measurement accuracy | 0.2% | |
| Current | Channel input voltage range | 0-420mVAC | 
| Measurement range | Different current sensors have different measuring ranges | |
| Measurement accuracy | 0.2%+ Accuracy of current sensor | |
| Frequency | Measurement range | 45Hz-65Hz | 
| Measurement accuracy | ±0.001Hz | |
| Power factor | Measurement range | -1-+1 | 
| Measurement accuracy | ±0.005 | |
| Power | Active power accuracy | 0.5% | 
| Reactive power accuracy | 1% | |
| Apparent power accuracy | 0.5% | |
| Energy | Active energy accuracy | 0.5% | 
| Reactive energy accuracy | 1% | |
| Apparent energy accuracy | 0.5% | 
-      - Record storage
 
| Data record | |
| Record name | Settable | 
| Record start time | Settable | 
| Record duration | Selectable | 
| Recording interval | Settable | 
| Basic data record | Phase voltage Line voltage Current Frequency Power factor Fundamental harmonic power factor Power(Active, Reactive, Apparent) Active Energy (Import energy, Export energy) Reactive energy (Import energy, Export energy) Apparent Energy Voltage harmonics (Total harmonic, odd total harmonic, even total harmonic) Current harmonics (Total harmonic, odd total harmonic, even total harmonic) Phase voltage peak Peak factor of phase voltage Current crest factor Current K factor Voltage unbalance (negative sequence, zero sequence) Current unbalance (negative sequence, zero sequence) Angle (phase voltage angle, phase current angle, angle between voltages, angle between currents, angle between voltages and currents) Max min (Phase voltage, Line voltage, Current, Frequency, Power factor, Fundamental harmonic power factor, Active power, Reactive power, Apparent power) Demand (Current, Active power, Reactive power, Apparent power) Peak Demand (Current, Active power, Reactive power, Apparent power) | 
| Voltage harmonic data record | Voltage harmonics (Total harmonic distortion THD, Odd total harmonic TOHD, Even total harmonic TEHD, 1-50th Harmonic percentage and voltage value) | 
| Current harmonic data record | Current harmonics (total harmonic distortion THD, Odd total harmonicTOHD, Even total harmonic TEHD, 1-50th Harmonic percentage and current value) | 
| Data storage format | CSV | 
| Event record [[1]] | |
| Recorded data | Event type Start time Duration Amplitude value | 
| Data storage format | CSV | 
| Waveform recording | |
| Record name | Settable | 
| Record the start time | Settable | 
| Record the duration | Settable | 
| Sampling rate | Settable | 
| Logged data | Phase ABC voltage waveform Phase ABC current waveform | 
| Data storage format | CSV | 
 
             Safety and warning notes        
        
In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions,please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under Rogowski website.
      In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions,please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under Rogowski website.
 
    
    
   
 
   